GTranslate
English French German Greek Italian Portuguese Russian Spanish

Air dehumidifiers
MID / MSP series

Air dehumidifiers of MID and MSP series are designed for industrial or pool areas. They are usually installed in the environments like public and private pools, dairy plants, basements, cellars and other applications, where humidity control is essential so that the structure or the goods do not get damaged
Air dehumidifiers<br/> MID / MSP series

MSP single flow ductable dehumidifier, designed for dehumidification and heating of indoor pools and aggressive ambients.

100 ... 4650 l/day
Dehumidification capacity:
  • Installation in the room where dehumidification is needed (fixed or movable with pivoting wheels, optional) or in a technical room
  • Galvanized steel panels, inside and outside painted
  • Pre-coated finned coils suitable for aggressive environment
  • Electronical components protected against chlorine
  • Stainless steel condensate tray
  • Double inlet centrifugal fan (EC radial fan, opt.) top or in-line supply
  • Desuperheater for chlorined water
Principle scheme

  1. Compressor, R410A refrigerant gas
  2. Desuperheater (optional)
  3. Condenser
  4. Thermostatic expansion valve
  5. Evaporator
  6. Fan: direct drive for sizes up to 0950, belt transmission for sizes from 1100; radial EC fan optional
  7. Post-heating or post-cooling water coil with 3 ways valve
Operating mode

Standart options:
Standart options:
  • Mechanical humidistat
  • Filter holder frame for the intake air duct
  • Electronic chrono-humidistat
  • Hot/chilled  water coil with a 3-way valve
  • Silent version -2 dB(A)
  • Soft-starter
  • Manometers
  • Hot gas defrost
  • Swimming pool water desuperheater
  • Centrifugal fan with high static pressure
Advanced control:
Advanced control:
  • Radial EC fans
  • 0-10 V control terminal
  • AAC: automatic airflow control
  • Clock card for time scheduling
  • Filter clogging sensor
  • Remote user terminal
  • TH probe for duct installation
  • Serial board for Modbus, Lonworks, Bacnet, KNX,

  Ethernet TM connectivity

 

Legend:

 

  • А – Fan
  • B – Compressor
  • C – Evaporator
  • D – Condenser
  • E – Hot water heat exchanger or electric heater (option)
Options:

 

 

  • Filter holder frame for suction ducting with G2 or G4 filters (1)
  • Mechanical hygrostat for wall installation (2)
  • Electronic chrono – hygrostat (3)
  • Water coil with modulating three-ways valve(4)

 

  1.  Only heating
  2.  Only heating, oversized
  3.  Cooling/Heating
  4.  Cooling/Heating, oversized

 

*3, 4 Including condensate tray and insulation

 

  • Silent version (5)
  • Soft-start
  • Manometers (6)
  • Hot gas defrost (mandatory in case of air temperature below 8°C)
  • Desuperheater for technical or pool water (4)
  • High static pressure centrifugal fan
  • Radial EC Fan  (7)
  • ACF: Automatic Control Flow; it allows to choose the air flow directly on the display and to keep it also in case of variable pressure drops due to the filters.
  • Advanced control
  • Clock card with time scheduling: 2 operating mode (weekday or holiday), 6 time slots per operating mode. Settable parameters: on/off, indoor temperature, indoor relative humidity.
  • Dirty filters sensor (8)
  • Temperature and humidity probe for duct installation (9)
  • Remote user terminal including 20 m cable (10)
  • Additional thermal insulation, thickness 20 mm or 40 mm
  • Pivoting wheels (11)
  • Serial board for BMS (12)

 

  1.  Modbus
  2.  LonWorks
  3.  BACnet
  4.  KNX

 

  • Ethernet ™ interface card, protocols available: SNMP v1 & v2c, BACnet / IP, BACnet Ethernet and Modbus TCP / IP
  • Contact for 0-10 V humidifier control
  • Version for outdoor installation
Options for special applications
Options for special applications
  • Special coils for aggressive ambient
  • Stainless steel AISI 316L panels
  • Technical water condenser
  • Electric heaters
  • Pool water condenser
Type of fans

Seasonal operating mode

 

WINTER: start up, no occupants, covered pool, heating with hot water coil.
Compressor: OFF
Hot water coil: ON (optional)
Desuperheater: OFF (optional)

 

 

WINTER: normal operation, pool open, dehumidification.
Compressor: ON
Hot water coil: OFF (optional)
Desuperheater: OFF (optional)

 

 

SPRING, SUMMER, AUTUMN: normal operation, pool open, dehumidification with heat recovery (desuperheater)
Compressor: ON
Hot water coil: OFF (optional)
Desuperheater: ON (optional)

Perfomance graph

Specifications Units MID -
MSP 010
MID -
MSP 013
MID -
MSP 016
MID -
MSP 019
MID -
MSP 021
MID -
MSP 026
MID -
MSP 030
MID -
MSP 035
MID -
MSP 045
MID -
MSP 058
Dehumidification capacity l/day 100 128 157 190 210 268 302 358 452 581
Air flow rate

m3/h

900 1200 1600 1600 2000 2800 2800 3800 4000 4800
Water heater capacity kW 5,5 9,8 9,8 9,8 16,5 17 17 26,5 26,5 27
Electric heater capacity kW upon request
Power supply V / phases / Hz 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
Dimensions (WxLxH) mm 700х550х900 700х850х900 830х850х1350

 

Specifications Units MID -
MSP 075
MID -
MSP 095
MID -
MSP 110
MID -
MSP 140
MID -
MSP 150
MID -
MSP 170
MID -
MSP 190
MID -
MSP 220
MID -
MSP 300
MID -
MSP 450
Dehumidification capacity l/day 760 955 1120 1380 1480 1710 1870 2180 2960 4650
Air flow rate

m3/h

7000 8200 11000 12500 13000 15000 15000 17000 25000 35000
Water heater capacity kW 48 55 76 83 98 107 107 118 168 235
Electric heater capacity kW upon request
Power supply V / phases / Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3+N/50
Dimensions (WxLxH) mm 1000х1400х1350 1000х1950х1640 1000х1950х1640

1000х3390х

1640

1000x4430х
2380

All the data refer to: air temperature 30 °C, relative humidity 80%, water temperature 80/70 °C

Note:
MID – standard (industrial) version
MSP – pool water version

Want to buy

Feedback form

Invitation to cooperation